Procedures · 02
Redox titration with KMnO₄
Determine the strength of KMnO₄ (or of a reducing agent) in acidic solution.
You will need
- 50 mL burette (amber or clean clear glass)
- 10 mL pipette with filler
- Conical flasks, measuring cylinder
- Bunsen burner, tripod, gauze and thermometer (for oxalic acid)
Safety
- KMnO₄ is an oxidiser and stains skin brown
- Hot flasks: handle with tongs or a cloth
- Dilute H₂SO₄ is corrosive, so wear goggles
Procedure
0 of 6 doneCalculation
, so .
With Mohr’s salt, , so .
Common mistakes
- Using HCl instead of H₂SO₄: KMnO₄ oxidises Cl⁻ to Cl₂, using up extra titrant
- Using HNO₃: it is itself an oxidising agent
- Too little acid: a brown precipitate of MnO₂ forms instead of colourless Mn²⁺
- Letting the oxalic acid cool below about 60 °C, so the end point is slow and overshoots