Titrations from first principles: primary standards and standard solutions, the law of equivalence, acid base titrations and indicator choice, double indicator titrations, KMnO₄ and K₂Cr₂O₇ redox titrations, iodometry, EDTA complexometry for hardness, precipitation titrations and the habits that give concordant readings
NEET · MediumJEE Main · MediumJEE Advanced · Medium
NEET style
The practical chemistry unit of the syllabus covers titrimetric exercises: acids, bases and indicators, oxalic acid vs KMnO₄ and Mohr’s salt vs KMnO₄
JEE style
Equivalence calculations, double indicator problems (NaOH, Na₂CO₃ and NaHCO₃ mixtures) and iodometry appear inside stoichiometry numericals
Standards and the law of equivalence
In a titration, a solution of known concentration (titrant, in the burette) reacts with the substance being analysed (titrand, in the conical flask). The equivalence point is where the amounts are stoichiometrically equal; the end point is where the indicator changes. A good indicator makes the two coincide.
Primary standards
Oxalic acid HX2CX2OX4⋅2HX2O (M = 126)
Anhydrous NaX2COX3
KX2CrX2OX7
Mohr’s salt FeSOX4⋅(NHX4)X2SOX4⋅6HX2O (M = 392)
Potassium hydrogen phthalate (M = 204.2)
Not primary standards
NaOH: hygroscopic, absorbs CO₂
KMnOX4: contains MnOX2, decomposes in light
HCl: volatile, variable strength
NaX2SX2OX3⋅5HX2O: usually standardised before use
A primary standard is pure, stable, nonhygroscopic, readily soluble and preferably of high molar mass (to reduce weighing error).
Law of equivalence
N1V1=N2V2,N=M×n-factor
Acid base titrations and indicators
Indicator
pH range
Colour change
Methyl orange
3.1 to 4.4
Red → yellow
Methyl red
4.4 to 6.2
Red → yellow
Phenolphthalein
8.3 to 10.0
Colourless → pink
Titration
pH at equivalence
Suitable indicator
Strong acid and strong base
7
Phenolphthalein or methyl orange
Weak acid and strong base
> 7
Phenolphthalein
Strong acid and weak base
< 7
Methyl orange or methyl red
Weak acid and weak base
≈ 7, no sharp jump
None satisfactory
1
Double indicator titration of carbonate with HCl: at the phenolphthalein end point only COX3X2−HCOX3X− is complete.
2
At the methyl orange end point HCOX3X−HX2COX3 is also complete.
3
For NaOH + NaX2COX3: acid used up to phenolphthalein (V1) = NaOH + half the carbonate; extra acid for methyl orange (V2) = the other half. So mmol NaX2COX3=MV2 and mmol NaOH =M(V1−V2).
4
For NaX2COX3 + NaHCOX3: mmol NaX2COX3=MV1 and mmol NaHCOX3=M(V2−V1).
Oxalic acid vs KMnO₄ in dilute H₂SO₄ at 333 to 343 K: the reaction is slow at first and is autocatalysed by Mn²⁺; KMnO₄ is its own indicator (first permanent pink)
MnOX4X−+5FeX2++8HX+MnX2++5FeX3++4HX2O
Mohr’s salt vs KMnO₄ at room temperature, because heating would let air oxidise Fe²⁺
Acidify with dilute HX2SOX4 only: HCl would be oxidised to ClX2, and HNOX3 is itself an oxidant.
Permanganate is a self indicator: the first lasting pink appears when only about 10−6 mol L−1 of MnOX4X− is left over, so the end point barely overshoots the equivalence point.
KX2CrX2OX7 is not a self indicator, so its titration against FeX2+ uses diphenylamine, which the first excess of dichromate oxidises to an intense blue colour at the end point.
Iodometry: an oxidant liberates IX2 from excess KI, which is titrated with thiosulfate. For copper: 2CuX2++4IX−2CuI+IX2 and IX2+2SX2OX3X2−2IX−+SX4OX6X2−. Starch is added near the end point (blue → colourless); added too early, the starch iodine complex forms in bulk and gives up its iodine only slowly.
Iodimetry: a reducing agent is titrated directly with standard iodine.
Complexometric and precipitation titrations
NaX2HX2EDTA combines with CaX2+ and MgX2+ in a 1 : 1 ratio. At pH 10 (NH₃ and NH₄Cl buffer) with Eriochrome Black T, the solution changes from wine red (the metal indicator complex) to blue (free indicator) at the end point.
Total hardness
ppm as CaCO3=Vsample(mL)MEDTA×VEDTA(mL)×100×1000
Mohr’s method: ClX− titrated with AgNOX3 in neutral solution with KX2CrOX4 indicator; red brown AgX2CrOX4 appears after all AgCl has precipitated.
Volhard’s method: excess AgX+ is back titrated with SCNX− using FeX3+ indicator (red [Fe(SCN)]X2+).
Fajans’ method uses adsorption indicators such as fluorescein.
Good practice and common errors
Rinse the burette with the titrant and the pipette with the solution it will deliver; rinse the conical flask with water only.
Remove the air bubble from the burette tip; read the bottom of the meniscus at eye level (top of the meniscus for dark KMnOX4) to avoid parallax.
Use a white tile, swirl constantly and add dropwise near the end point. Repeat until three readings agree within 0.1 mL (concordant).
Do not blow out the last drop of a pipette: it is calibrated to deliver its volume with that drop left behind.
Weak acid → phenolphthalein (basic end point). Weak base → methyl orange (acidic end point). “The indicator sides with the strong partner.”
Hot oxalate, cold Mohr’s salt
Warm oxalic acid to 60 to 70 °C to speed it up; keep Mohr’s salt cold so air does not oxidise Fe²⁺.
No HCl with permanganate
Cl⁻ gets oxidised to Cl₂ → extra KMnO₄ used → high result.
Starch late
In iodometry add starch only when the solution is pale straw yellow.
Carbonate takes two steps
Phenolphthalein sees half a carbonate; methyl orange sees all of it.
Rinse rule
Burette and pipette: rinse with the solution. Flask: rinse with water only.
NCERT high yield lines
Original NCERT aligned summaries of the lines examiners love. Tap “Quiz me” to test yourself instantly.
In the titration of oxalic acid with potassium permanganate, the solution is heated to 60 to 70 °C because the reaction is slow at room temperature; KMnO₄ acts as a self indicator.NCERT Laboratory Manual · Titrimetric analysis
Ferrous ammonium sulfate (Mohr’s salt) is titrated against KMnO₄ in the cold, since Fe²⁺ is oxidised by air on heating.NCERT Laboratory Manual · Titrimetric analysis
Dilute sulfuric acid, not hydrochloric or nitric acid, is used to acidify permanganate titrations.NCERT Laboratory Manual · Titrimetric analysis
Redox titrations need a redox sensitive end point: permanganate shows its own first lasting pink, dichromate oxidises diphenylamine to an intense blue just after equivalence, and in the iodometric estimation of Cu²⁺ the blue starch iodine colour disappears once thiosulfate has used up the iodine.NCERT Class 11 · Redox reactions as the basis for titrations
Solved problems
Example 1
NEETJEE MainFoundation
What mass of oxalic acid dihydrate is needed to prepare 250 mL of a 0.1 M solution?
Example 2
NEETJEE MainFoundation
20 mL of 0.05 M oxalic acid is titrated with KMnOX4 in acid; 16 mL is required. Find the molarity of KMnOX4.
Example 3
JEE MainJEE AdvancedExam level
20 mL of a solution containing NaOH and NaX2COX3 needs 30 mL of 0.1 M HCl to reach the phenolphthalein end point and a further 10 mL to reach the methyl orange end point. Find both concentrations.
Example 4
JEE MainExam level
A sample of CuSOX4⋅5HX2O is treated with excess KI. The liberated iodine needs 20 mL of 0.1 M NaX2SX2OX3. Find the mass of the sample (M = 249.7).
Example 5
NEETJEE MainFoundation
100 mL of hard water requires 10 mL of 0.01 M EDTA (EBT, pH 10). Find the total hardness in ppm of CaCOX3.
Practice
Q1
Single correct
NEETFoundation
Important
The best indicator for titrating acetic acid with NaOH is:
Q2
Single correct
NEETFoundation
Important
Oxalic acid vs KMnOX4 titrations are done at 60 to 70 °C because:
Q3
Single correct
NEETFoundation
Important
Permanganate titrations are acidified with:
Q4
Numerical
JEE MainJEE AdvancedAdvanced
Important
25.0 mL of a solution of NaX2COX3 and NaHCOX3 needs 10.0 mL of 0.10 M HCl to reach the phenolphthalein end point and a further 30.0 mL to reach the methyl orange end point. What is the molarity of NaHCOX3 in the solution?
Q5
Single correct
NEETFoundation
Which is a primary standard?
Q6
Numerical
NEETJEE MainFoundation
25 mL of 0.1 M oxalic acid needs 20 mL of KMnOX4 in acid. Molarity of KMnOX4?
Q7
One or more correct
NEETJEE MainFoundation
Which can be used as primary standards?
Q8
Numerical
NEETJEE MainFoundation
Mass (g) of HX2CX2OX4⋅2HX2O needed for 250 mL of 0.1 M solution:
Q9
Single correct
NEETFoundation
At the end point of an EDTA titration with Eriochrome Black T, the colour changes from:
Q10
Numerical
JEE MainExam level
100 mL of water consumes 10 mL of 0.01 M EDTA. Hardness in ppm of CaCOX3?
Q11
Single correct
JEE MainFoundation
In iodometric titrations, starch is added:
Q12
Numerical
NEETJEE MainFoundation
What is the n-factor of KX2CrX2OX7 in acidic medium?
Q13
Numerical
JEE MainFoundation
Volume (mL) of 0.1 M HCl needed to reach the methyl orange end point with 10 mL of 0.1 M NaX2COX3:
Q14
Matrix match
NEETJEE MainFoundation
Match the titration with its indicator. Column I: (P) HCl vs NHX4OH (Q) CHX3COOH vs NaOH (R) CaX2+ vs EDTA (S) ClX− vs AgNOX3 (Mohr) Column II: (1) Eriochrome Black T (2) KX2CrOX4 (3) methyl orange (4) phenolphthalein
Q15
Numerical
NEETJEE MainExam level
0.50 g of impure sodium carbonate is dissolved in water and titrated with 0.10 M HCl using methyl orange; 80.0 mL of acid is needed. What is the percentage purity of the sample? (NaX2COX3 = 106 g mol−1)
Q16
One or more correct
NEETJEE MainExam level
In the titration of Mohr’s salt with KMnOX4, which mistakes make the recorded volume of KMnOX4 larger than the true value?
Q17
Numerical
JEE MainJEE AdvancedAdvanced
A 0.25 g sample of a copper alloy is dissolved and treated with excess KI. The iodine liberated needs 15.0 mL of 0.10 M NaX2SX2OX3. What is the percentage of copper by mass? (Cu = 63.5)
Q18
Numerical
JEE MainJEE AdvancedAdvanced
What volume (mL) of 0.020 M KMnOX4 is needed to oxidise 10.0 mL of 0.10 M FeCX2OX4 completely in acidic solution?
Q19
Numerical
NEETJEE MainExam level
100 mL of hard water needs 12.0 mL of 0.010 M EDTA. Another 100 mL is boiled, filtered and then needs 8.0 mL of the same EDTA. What is the temporary hardness in ppm of CaCOX3?
Ready for the real thing?