Procedures · 07

Thin layer chromatography (TLC)

Check purity, follow the progress of a reaction, or choose the solvent for column chromatography.

You will need

  • Silica gel TLC plate
  • Pencil and ruler
  • Glass capillaries for spotting
  • Developing jar with a lid, lined with filter paper
  • UV lamp (254 nm) or an iodine chamber

Safety

  • Develop in a fume hood: eluents are flammable
  • Never look into a UV lamp

Procedure

0 of 7 done

Retardation factor

Rf=distance moved by the spot from the baselinedistance moved by the solvent front from the baselineR_f = \frac{\text{distance moved by the spot from the baseline}}{\text{distance moved by the solvent front from the baseline}}

RfR_f is never more than 1. On silica, less polar compounds are adsorbed less, travel further and have higher RfR_f.

Common mistakes

  • Solvent above the baseline dissolves the spots off the plate
  • Overloaded spots streak
  • Not marking the solvent front before it evaporates

Purification chapter