Procedures · 04
Simple distillation
Separate a volatile liquid from nonvolatile impurities, or two liquids whose boiling points differ widely (a common rule of thumb is 25 °C or more), for example chloroform (b.p. 334 K) from aniline (b.p. 457 K), or water from salt solution.
You will need
- Round bottom flask (no more than two thirds full)
- Boiling chips
- Still head, thermometer and adapter
- Liebig condenser with water tubing
- Receiver flask
- Heating mantle or water bath; clamps and stands
Safety
- Never heat a closed system: the outlet must be open to the air
- Add boiling chips before heating, never to a hot liquid
- Never distil to dryness, especially ethers (peroxides)
Procedure
0 of 6 doneCommon mistakes
- Thermometer bulb too high (reads low) or dipping into the liquid (reads the liquid, not the vapour)
- Cooling water connected in at the top: the jacket never fills
- Heating too fast: impure distillate and flooding